Skip to content

OpenWaterAnalytics/EPyT

Repository files navigation



license pypi Downloads Downloads build Documentation Status DOI

EPANET Python Toolkit (EPyT)

The EPANET-Python Toolkit is an open-source software, originally developed by the KIOS Research and Innovation Center of Excellence, University of Cyprus which operates within the Python environment, for providing a programming interface for the latest version of EPANET, a hydraulic and quality modeling software created by the US EPA, with Python, a high-level technical computing software. The goal of the EPANET Python Toolkit is to serve as a common programming framework for research and development in the growing field of smart water networks.

The EPANET-Python Toolkit features easy to use commands/wrappers for viewing, modifying, simulating and plotting results produced by the EPANET libraries.

For support, please use the OWA community forum: https://github.com/orgs/OpenWaterAnalytics/discussions

Table of Contents

How to cite

Kyriakou, M. S., Demetriades, M., Vrachimis, S. G., Eliades, D. G., & Polycarpou, M. M. (2023). EPyT: An EPANET-Python Toolkit for Smart Water Network Simulations. Journal of Open Source Software, 8(92), 5947. https://doi.org/10.21105/joss.05947

@article{Kyriakou2023,
author = {Kyriakou, Marios S. and Demetriades, Marios and Vrachimis, Stelios G. and Eliades, Demetrios G. and Polycarpou, Marios M.},
doi = {10.21105/joss.05947},
journal = {Journal of Open Source Software},
month = dec,
number = {92},
pages = {5947},
title = {{EPyT: An EPANET-Python Toolkit for Smart Water Network Simulations}},
url = {https://joss.theoj.org/papers/10.21105/joss.05947},
volume = {8},
year = {2023}
}

Back to top

Requirements

Linux: sudo cp libepanet2.so /lib/x86_64-linux-gnu/libepanet.so

Back to top

How to install

Environments -> base (root) -> open terminal -> pip install epyt

  • PyPI: pip install epyt

Back to top

How to use the Toolkit

Minimum Example:

>>> from epyt import epanet
>>> 
>>> d = epanet('Net1.inp')
>>> d.getNodeCount()
>>> d.getNodeElevations()

Minumun Example using custom Library:

>>> from epyt import epanet
>>>
>>>epanetlib=os.path.join(os.getcwd(), 'epyt','libraries','win','epanet2.dll')
>>>msxlib=os.path.join(os.getcwd(), 'epyt','libraries','win','epanetmsx.dll')
>>>d = epanet(inpname, customlib=epanetlib)
>>>d.loadMSXFile(msxname, customMSXlib=msxlib)

More examples:

https://github.com/KIOS-Research/EPYT/tree/main/epyt/examples

Back to top

How to fix/report bugs

To fix a bug Fork the EPyT, Edit the code and make the appropriate change, and then Pull it so that we evaluate it.

Keep in mind that some bugs may exist in the EPANET libraries, in case you are not receiving the expected results.

Back to top

Licenses

  • EPANET: Public Domain
  • EPANET-Python Toolkit (EPyT): EUPL

Back to top

Contributors

The EPyT is based/inspired on the EPANET-Matlab Toolkit.

Contributing

If you want to contribute, please check out our Code of Conduct. Everyone is welcome to contribute whether reporting a new issue, suggesting a new feature, or writing code. If you want to contribute code, you can create a new fork in the repo to your own account. Make your commits on your dev branch (based on dev) and when you are finished then you can create a pull request to test the code and discuss your changes.

Recommendation

Settings on Spyder IDE

  • Tools -> Preferrences image
  • View -> Window layouts -> Matlab layout
  • Enable interactive plot on matlibplot : Tools -> Preferences -> IPython console -> Graphics -> Graphics backend -> Backend: Automatic

Back to top

List of EPyT Functions

Function Description
addControls Adds a new simple control
addCurve Adds a new curve appended to the end of the existing curves
addLinkPipe Adds a new pipe
addLinkPipeCV Adds a new control valve pipe
addLinkPump Adds a new pump
addLinkValveFCV Adds a new FCV valve
addLinkValveGPV Adds a new GPV valve
addLinkValvePBV Adds a new PBV valve
addLinkValvePCV Adds a new PCV valve and returns the index of the new PCV valve
addLinkValvePRV Adds a new PRV valve
addLinkValvePSV Adds a new PSV valve
addLinkValveTCV Adds a new TCV valve
addNodeJunction Adds a new junction
addNodeJunctionDemand Adds a new demand to a junction given the junction index, base demand, demand time pattern and demand category name
addNodeReservoir Adds a new reservoir
addNodeTank Adds a new tank
addPattern Adds a new time pattern to the network
addRules Adds a new rule-based control to a project
appRotateNetwork Rotates the network by theta degrees counter-clockwise
appShiftNetwork Shifts the network
clearReport Clears the contents of a project's report file
closeHydraulicAnalysis Closes the hydraulic analysis system, freeing all allocated memory
closeNetwork Closes down the Toolkit system
closeQualityAnalysis Closes the water quality analysis system, freeing all allocated memory
copyReport Copies the current contents of a project's report file to another file
createProject Creates a new epanet projec
deleteAllTemps Delete all temporary files (.inp, .bin) created in networks folder
deleteControls Deletes an existing simple control
deleteCurve Deletes a data curve from a project
deleteLink Deletes a link
deleteNode Deletes nodes
deleteNodeJunctionDemand Deletes a demand from a junction given the junction index and demand index.
deletePattern Deletes a time pattern from a project
deletePatternsAll Deletes all time patterns from a project
deleteProject Deletes the epanet project
deleteRules Deletes an existing rule-based control given it's index
getAdjacencyMatrix Compute the adjacency matrix (connectivity graph) considering the flows, using mean flow
getAllAttributes Get all attributes of a given Python object
getCMDCODE Retrieves the CMC code
getComputedHydraulicTimeSeries Computes hydraulic simulation and retrieves all time-series
getComputedQualityTimeSeries Computes Quality simulation and retrieves all or some time-series
getComputedTimeSeries Run analysis with binary fil
getConnectivityMatrix Retrieve the Connectivity Matrix of the networ
getConsumerDemandDelivered Retrieves the delivered consumer demand for a specific node
getConsumerDemandRequested Retrieves the requested consumer demand for a specific node
getControlCount Retrieves the number of controls => will replace getControlRulesCount
getControlRulesCount Retrieves the number of controls
getControlState Retrieves the enabled state of a specified control in the EPANET model
getControls Retrieves the parameters of all control statements
getCounts Retrieves the number of network components
getCurveComment Retrieves the comment string of a curve
getCurveCount Retrieves the number of curves
getCurveIndex Retrieves the index of a curve with specific ID
getCurveLengths Retrieves number of points in a curve
getCurveNameID Retrieves the IDs of curves
getCurveType Retrieves the curve-type for all curves
getCurveTypeIndex Retrieves the curve-type index for all curves
getCurveValue Retrieves the X, Y values of points of curves
getCurvesInfo Retrieves all the info of curves
getDemandModel Retrieves the type of demand model in use and its parameters
getENfunctionsImpemented Retrieves the epanet functions that have been developed
getError Retrieves the text of the message associated with a particular error or warning code
getFlowUnits Retrieves flow units used to express all flow rates
getLibFunctions Retrieves the functions of DLL
getLinkActualQuality Retrieves the current computed link quality (read only)
getLinkBulkReactionCoeff Retrieves the value of all link bulk chemical reaction coefficient
getLinkComment Retrieves the comment string assigned to the link object
getLinkCount Retrieves the number of links
getLinkDiameter Retrieves the value of link diameters
getLinkEnergy Retrieves the current computed pump energy usage (read only)
getLinkExpansionProperties Retrieves the expansion properties for a specified link (pipe)
getLinkFlows Retrieves the current computed flow rate (read only)
getLinkHeadloss Retrieves the current computed head loss (read only)
getLinkInControl Function to determine wether a link apperas in any simple or rule based control
getLinkIndex Retrieves the indices of all links, or the indices of an ID set of links
getLinkInitialSetting Retrieves the value of all link roughness for pipes or initial speed for pumps or initial setting for valves
getLinkInitialStatus Retrieves the value of all link initial status
getLinkLeakArea Function to retrieve the leak area for a specified link (pipe)
getLinkLeakageRate Retrieves the leakage rate of a specific pipe (link) at a given point in time
getLinkLength Retrieves the value of link lengths
getLinkMinorLossCoeff Retrieves the value of link minor loss coefficients
getLinkNameID Retrieves the ID label(s) of all links, or the IDs of an index set of links
getLinkNodesIndex Retrieves the indexes of the from/to nodes of all links
getLinkPipeCount Retrieves the number of pipes
getLinkPipeIndex Retrieves the pipe indices
getLinkPipeNameID Retrieves the pipe ID
getLinkPumpCount Retrieves the number of pumps
getLinkPumpECost Retrieves the pump average energy price
getLinkPumpECurve Retrieves the pump efficiency v
getLinkPumpEPat Retrieves the pump energy price time pattern index
getLinkPumpEfficiency Retrieves the current computed pump efficiency (read only)
getLinkPumpHCurve Retrieves the pump head v
getLinkPumpHeadCurveIndex Retrieves the index of a head curve for all pumps
getLinkPumpIndex Retrieves the pump indices
getLinkPumpNameID Retrieves the pump ID
getLinkPumpPatternIndex Retrieves the pump speed time pattern index
getLinkPumpPatternNameID Retrieves pump pattern name ID
getLinkPumpPower Retrieves the pump constant power rating (read only)
getLinkPumpState Retrieves the current computed pump state (read only) (see @ref EN_PumpStateType)
getLinkPumpSwitches Retrieves the number of pump switches
getLinkPumpType Retrieves the type of a pump
getLinkPumpTypeCode Retrieves the code of type of a pump
getLinkQuality Retrieves the value of link quality
getLinkResultIndex Retrieves the order in which a link's results were saved to an output file
getLinkRoughnessCoeff Retrieves the value of link roughness coefficient
getLinkSettings Retrieves the current computed value of all link roughness for pipes or actual speed for pumps or actual setting for valves
getLinkStatus Retrieves the current link status (see @ref EN_LinkStatusType) (0 = closed, 1 = open)
getLinkType Retrieves the link-type code for all links
getLinkTypeIndex Retrieves the link-type code for all links
getLinkValues Retrieves property values for all links within the EPANET model during a hydraulic analysis
getLinkValveCount Retrieves the number of valves
getLinkValveCurveGPV Retrieves the valve curve for a specified general purpose valve (GPV)
getLinkValveCurvePCV Retrieves the valve curve for a specified pressure control valve (PCV)
getLinkValveIndex Retrieves the valve indices
getLinkValveNameID Retrieves the valve ID
getLinkVelocity Retrieves the current computed flow velocity (read only)
getLinkVertices Retrieves the coordinate's of a vertex point assigned to a link
getLinkVerticesCount Retrieves the number of internal vertex points assigned to a link
getLinkWallReactionCoeff Retrieves the value of all pipe wall chemical reaction coefficient
getLinksInfo Retrieves all link info
getNetworksDatabase Retrieves all EPANET Input Files from EPyT database
getNodeActualDemand Retrieves the computed value of all node actual demands
getNodeActualDemandSensingNodes Retrieves the computed demand values at some sensing nodes
getNodeActualQuality Retrieves the computed values of the actual quality for all nodes
getNodeActualQualitySensingNodes Retrieves the computed quality values at some sensing node
getNodeBaseDemands Retrieves the value of all node base demands
getNodeComment Retrieves the comment string assigned to the node object
getNodeCount Retrieves the number of nodes
getNodeDemandCategoriesNumber Retrieves the value of all node base demands categorie number
getNodeDemandDeficit Retrieves the amount that full demand is reduced under PDA
getNodeDemandPatternIndex Retrieves the value of all node base demands pattern index
getNodeDemandPatternNameID Retrieves the value of all node base demands pattern name ID
getNodeElevations Retrieves the value of all node elevations
getNodeEmitterCoeff Retrieves the value of all node emmitter coefficients
getNodeEmitterFlow Retrieves node emmiter flow
getNodeHydraulicHead Retrieves the computed values of all node hydraulic heads
getNodeInControl Function to determine wether a node apperas in any simple or rule based control
getNodeIndex Retrieves the indices of all nodes or some nodes with a specified ID
getNodeInitialQuality Retrieves the value of all node initial quality
getNodeJunctionCount Retrieves the number of junction nodes
getNodeJunctionDemandIndex Retrieves the demand index of the junctions
getNodeJunctionDemandName Gets the name of a node's demand category
getNodeJunctionIndex Retrieves the indices of junctions
getNodeJunctionNameID Retrieves the junction ID label
getNodeLeakageFlow Retrieves the leakage flow for a specific node
getNodeMassFlowRate Retrieves the computed mass flow rates per minute of chemical sources for all nodes
getNodeNameID Retrieves the ID label of all nodes or some nodes with a specified index
getNodePatternIndex Retrieves the value of all node demand pattern indices
getNodePressure Retrieves the computed values of all node pressures
getNodeReservoirCount Retrieves the number of Reservoirs
getNodeReservoirIndex Retrieves the indices of reservoirs
getNodeReservoirNameID Retrieves the reservoir ID label
getNodeResultIndex Retrieves the order in which a node's results were saved to an output file
getNodeSourcePatternIndex Retrieves the value of all node source pattern index
getNodeSourceQuality Retrieves the value of all node source quality
getNodeSourceType Retrieves the value of all node source type
getNodeSourceTypeIndex Retrieves the value of all node source type index
getNodeTankBulkReactionCoeff Retrieves the tank bulk rate coefficient
getNodeTankCanOverFlow Retrieves the tank can overflow (= 1) or not (= 0)
getNodeTankCount Retrieves the number of Tanks
getNodeTankData Retrieves a group of properties for a tank
getNodeTankDiameter Retrieves the tank diameters
getNodeTankIndex Retrieves the tank indices
getNodeTankInitialLevel Retrieves the value of all tank initial water levels
getNodeTankInitialWaterVolume Retrieves the tank initial water volume
getNodeTankMaximumWaterLevel Retrieves the tank maximum water level
getNodeTankMaximumWaterVolume Retrieves the tank maximum water volume
getNodeTankMinimumWaterLevel Retrieves the tank minimum water level
getNodeTankMinimumWaterVolume Retrieves the tank minimum water volume
getNodeTankMixZoneVolume Retrieves the tank mixing zone volume
getNodeTankMixingFraction Retrieves the tank Fraction of total volume occupied by the inlet/outlet zone in a 2-compartment tank
getNodeTankMixingModelCode Retrieves the tank mixing model code
getNodeTankMixingModelType Retrieves the tank mixing model type
getNodeTankNameID Retrieves the tank IDs
getNodeTankReservoirCount Retrieves the number of tanks
getNodeTankVolume Retrieves the tank volume
getNodeTankVolumeCurveIndex Retrieves the tank volume curve index
getNodeType Retrieves the node-type code for all nodes
getNodeTypeIndex Retrieves the node-type code for all nodes
getNodesConnectingLinksID Retrieves the id of the from/to nodes of all links
getNodesConnectingLinksIndex Retrieves the indexes of the from/to nodes of all links
getNodesInfo Retrieves nodes info (elevations, demand patterns, emmitter coeff, initial quality, source quality, source pattern index, source type index, node type index)
getOptionsAccuracyValue Retrieves the total normalized flow change for hydraulic convergence
getOptionsCheckFrequency Retrieves the frequency of hydraulic status checks
getOptionsDampLimit Retrieves the accuracy level where solution damping begins
getOptionsDemandCharge Retrieves the energy charge per maximum KW usage
getOptionsDemandPattern Retrieves the default Demand pattern
getOptionsEmitterBackFlow Retrieves the current setting for allowing reverse flow through emitters
getOptionsEmitterExponent Retrieves the power exponent for the emmitters
getOptionsExtraTrials Retrieves the extra trials allowed if hydraulics don't converge
getOptionsFlowChange Retrieves the maximum flow change for hydraulic convergence
getOptionsGlobalEffic Retrieves the global efficiency for pumps(percent)
getOptionsGlobalPattern Retrieves the index of the global energy price pattern
getOptionsGlobalPrice Retrieves the global average energy price per kW-Hour
getOptionsHeadError Retrieves the maximum head loss error for hydraulic convergence
getOptionsHeadLossFormula Retrieves the headloss formula
getOptionsLimitingConcentration Retrieves the limiting concentration for growth reactions
getOptionsMaxTrials Retrieves the maximum hydraulic trials allowed for hydraulic convergence
getOptionsMaximumCheck Retrieves the maximum trials for status checking
getOptionsPatternDemandMultiplier Retrieves the global pattern demand multiplier
getOptionsPipeBulkReactionOrder Retrieves the bulk water reaction order for pipes
getOptionsPipeWallReactionOrder Retrieves the wall reaction order for pipes (either 0 or 1)
getOptionsPressureUnits get the pressure unit used in Epanet
getOptionsQualityTolerance Retrieves the water quality analysis tolerance
getOptionsSpecificDiffusivity Retrieves the specific diffusivity (relative to chlorine at 20 deg C)
getOptionsSpecificGravity Retrieves the specific gravity
getOptionsSpecificViscosity Retrieves the specific viscosity
getOptionsStatusReport get the type of the status report(full/no/normal)
getOptionsTankBulkReactionOrder Retrieves the bulk water reaction order for tanks
getPattern Retrieves the multiplier factor for all patterns and all times
getPatternAverageDefaultValue Retrieves the average value of the default pattern
getPatternAverageValue Retrieves the average values of all the time patterns
getPatternComment Retrieves the comment string assigned to the pattern object
getPatternCount Retrieves the number of patterns
getPatternIndex Retrieves the index of all or some time patterns given their IDs
getPatternLengths Retrieves the number of time periods in all or some time patterns
getPatternNameID Retrieves the ID label of all or some time patterns indices
getPatternValue Retrieves the multiplier factor for a certain pattern and time
getQualityCode Retrieves the code of water quality analysis type
getQualityInfo Retrieves quality analysis information (type, chemical name, units, trace node ID)
getQualityTraceNodeIndex Retrieves the trace node index of water quality analysis type
getQualityType Retrieves the type of water quality analysis type
getRuleCount Retrieves the number of rules
getRuleEnabled Retrieves the enabled state of a specific rule in the EPANET model
getRuleID Retrieves the ID name of a rule-based control given its index
getRuleInfo Retrieves summary information about a rule-based control given it's index
getRules Retrieves the rule - based control statements
getStatistic Returns error code
getStatisticDeficientNodes Retrieves the number of deficient nodes in the simulation
getStatisticDemandReduction Retrieves the demand reduction statistic from the simulation
getStatisticIterations Retrieves the number of iterations taken in the simulation
getStatisticRelativeError Retrieves the relative error statistic from the simulation
getStatisticTotalLeakageLoss Retrieves the total leakage loss statistic from the simulation.
getTimeHTime Retrieves the elapsed time of current hydraulic solution
getTimeHaltFlag Retrieves the number of halt flag indicating if the simulation was halted
getTimeHydraulicStep Retrieves the value of the hydraulic time step
getTimeNextEvent Retrieves the shortest time until a tank becomes empty or full
getTimeNextEventTank Retrieves the index of tank with shortest time to become empty or full
getTimePatternStart Retrieves the value of pattern start time
getTimePatternStep Retrieves the value of the pattern time step
getTimeQTime Retrieves the elapsed time of current quality solution
getTimeQualityStep Retrieves the value of the water quality time step
getTimeReportingPeriods Retrieves the number of reporting periods saved to the binary
getTimeReportingStart Retrieves the value of the reporting start time
getTimeReportingStep Retrieves the value of the reporting time step
getTimeRuleControlStep Retrieves the time step for evaluating rule-based controls
getTimeSimulationDuration Retrieves the value of simulation duration
getTimeStartClockStartTime Retrieves the simulation starting time of day
getTimeStartTime Retrieves the simulation starting time of day
getTimeStatisticsIndex Retrieves the index of the type of time series post-processing
getTimeStatisticsType Retrieves the type of time series post-processing
getTimetoNextEvent Determines the type of event that will cause the end of the current time step/duration/index
getTitle Retrieves the title lines of the project
getUnits Retrieves the Units of Measurement
getVersion Retrieves the current EPANET version of DLL
initializeEPANET Initializes an EPANET project that isn't opened with an input fil
initializeHydraulicAnalysis Initializes storage tank levels, link status and settings, and the simulation clock time prior to running a hydraulic analysis
initializeQualityAnalysis Initializes water quality and the simulation clock time prior to running a water quality analysis
loadEPANETFile Load epanet file when use bin functions
loadMSXEPANETFile Re-Load EPANET MSX file - parfor
loadPatternFile loads time patterns from a file into a project under a specific pattern ID
nextHydraulicAnalysisStep Determines the length of time until the next hydraulic event occurs in an extended period simulation
nextQualityAnalysisStep Advances the water quality simulation to the start of the next hydraulic time period
openAnyInp Open as on matlab editor any EPANET input file using built function open
openCurrentInp Opens EPANET input file who is loade
openHydraulicAnalysis Opens the hydraulics analysis system
openQualityAnalysis Opens the water quality analysis system
openX enable the opening of input files with formatting errors
plot Plot Network, show all components, plot pressure/flow/elevation
plot_close Close all open figures
plot_save Save plot
plot_show Show plot
reloadNetwork Reloads the Network (ENopen)
runEPANETexe Runs epanet .exe file
runHydraulicAnalysis Runs a single period hydraulic analysis, retrieving the current simulation clock time t
runQualityAnalysis Makes available the hydraulic and water quality results that occur at the start of the next time period of a water quality analysis, where the start of the period is returned in t
runsCompleteSimulation Runs a complete hydraulic and water simulation to create binary & report files with name: [NETWORK_temp.txt], [NETWORK_temp.bin] OR you can use argument to runs a complete simulation via self.api.en_epane
saveHydraulicFile Saves the current contents of the binary hydraulics file to a file
saveHydraulicsOutputReportingFile Transfers results of a hydraulic simulation from the binary Hydraulics file to the binary Output file, where results are only reported at uniform reporting intervals
saveInputFile Writes all current network input data to a file using the format of an EPANET input file
setCMDCODE Sets the CMC code
setControlEnabled Sets the control state to either enable or disable in the EPANET model
setControls Sets the parameters of a simple control statement
setCurve Sets x, y values for a specific curve
setCurveComment Sets the comment string of a curve
setCurveNameID Sets the name ID of a curve given it's index and the new ID
setCurveType Sets the type of a specified curve in the EPANET model
setCurveTypeEfficiency Sets the type of curve to Efficiency in the EPANET model
setCurveTypeGeneral Sets the type of a curve to general in the EPANET model
setCurveTypeHeadloss Sets the type of a curve to Headloss in the EPANET model
setCurveTypePump Sets the type of a curve to Pump in the EPANET model
setCurveTypeValveCurve Sets the type of a curve to Valve in the EPANET model
setCurveTypeVolume Sets the type of a curve to Volume in the EPANET model
setCurveValue Sets x, y point for a specific point number and curve
setDemandModel Sets the type of demand model to use and its parameters
setFlowUnitsAFD Sets flow units to AFD(Acre-Feet per Day)
setFlowUnitsCFS Sets flow units to CFS(Cubic Feet per Second)
setFlowUnitsCMD Sets flow units to CMD(Cubic Meters per Day)
setFlowUnitsCMH Sets flow units to CMH(Cubic Meters per Hour)
setFlowUnitsCMS Sets flow units to CMS(Cubic Meters per Second)
setFlowUnitsGPM Sets flow units to GPM(Gallons Per Minute)
setFlowUnitsIMGD Sets flow units to IMGD(Imperial Million Gallons per Day)
setFlowUnitsLPM Sets flow units to LPM(Liters Per Minute)
setFlowUnitsLPS Sets flow units to LPS(Liters Per Second)
setFlowUnitsMGD Sets flow units to MGD(Million Gallons per Day)
setFlowUnitsMLD Sets flow units to MLD(Million Liters per Day)
setLinkBulkReactionCoeff Sets the value of bulk chemical reaction coefficient
setLinkComment Sets the comment string assigned to the link object
setLinkDiameter Sets the values of diameters
setLinkExpansionProperties Sets the expansion properties for a specified link (pipe)
setLinkInitialSetting Sets the values of initial settings, roughness for pipes or initial speed for pumps or initial setting for valves
setLinkInitialStatus Sets the values of initial status
setLinkLeakArea Sets the leak area for a specified link (pipe)
setLinkLength Sets the values of lengths
setLinkMinorLossCoeff Sets the values of minor loss coefficient
setLinkNameID Sets the ID name for links
setLinkNodesIndex Sets the indexes of a link's start- and end-nodes
setLinkPipeData Sets a group of properties for a pipe
setLinkPumpECost Sets the pump average energy price
setLinkPumpECurve Sets the pump efficiency v
setLinkPumpEPat Sets the pump energy price time pattern index
setLinkPumpHCurve Sets the pump head v
setLinkPumpHeadCurveIndex Sets the curves index for pumps index
setLinkPumpPatternIndex Sets the pump speed time pattern index
setLinkPumpPower Sets the power for pumps
setLinkRoughnessCoeff Sets the values of roughness coefficient
setLinkSettings Sets the values of current settings, roughness for pipes or initial speed for pumps or initial setting for valves
setLinkStatus Sets the values of current status for links
setLinkTypePipe Sets the link type pipe for a specified link
setLinkTypePipeCV Sets the link type cvpipe(pipe with check valve) for a specified link
setLinkTypePump Sets the link type pump for a specified link
setLinkTypeValveFCV Sets the link type valve FCV(flow control valve) for a specified link
setLinkTypeValveGPV Sets the link type valve GPV(general purpose valve) for a specified link
setLinkTypeValvePBV Sets the link type valve PBV(pressure breaker valve) for a specified link
setLinkTypeValvePCV Sets the link type valve PCV(Position control valve) for a specified link
setLinkTypeValvePRV Sets the link type valve PRV(pressure reducing valve) for a specified link
setLinkTypeValvePSV Sets the link type valve PSV(pressure sustaining valve) for a specified link
setLinkTypeValveTCV Sets the link type valve TCV(throttle control valve) for a specified link
setLinkValveCurveGPV Sets the valve curve for a specified general purpose valve (GPV)
setLinkValveCurvePCV Sets the valve curve for a specified pressure control valve (PCV)
setLinkVertices Assigns a set of internal vertex points to a link
setLinkWallReactionCoeff Sets the value of wall chemical reaction coefficient
setNodeBaseDemands Sets the values of demand for nodes
setNodeComment Sets the comment string assigned to the node object
setNodeCoordinates Sets node coordinates
setNodeDemandPatternIndex Sets the values of demand time pattern indices
setNodeElevations Sets the values of elevation for nodes
setNodeEmitterCoeff Sets the values of emitter coefficient for nodes
setNodeInitialQuality Sets the values of initial quality for nodes
setNodeJunctionData Sets a group of properties for a junction node
setNodeJunctionDemandName Assigns a name to a node's demand category
setNodeNameID Sets the ID name for nodes
setNodeSourcePatternIndex Sets the values of quality source pattern index
setNodeSourceQuality Sets the values of quality source strength
setNodeSourceType Sets the values of quality source type
setNodeTankBulkReactionCoeff Sets the tank bulk reaction coefficient
setNodeTankCanOverFlow Sets the tank can-overflow (= 1) or not (= 0)
setNodeTankData Sets a group of properties for a tank
setNodeTankDiameter Sets the diameter value for tanks
setNodeTankInitialLevel Sets the values of initial level for tanks
setNodeTankMaximumWaterLevel Sets the maximum water level value for tanks
setNodeTankMinimumWaterLevel Sets the minimum water level value for tanks
setNodeTankMinimumWaterVolume Sets the minimum water volume value for tanks
setNodeTankMixingFraction Sets the tank mixing fraction of total volume occupied by the inlet/outlet zone in a 2-compartment tank
setNodeTankMixingModelType Sets the mixing model type value for tanks
setNodeTypeJunction Transforms a node to JUNCTION The new node keeps the id,coordinates and elevation of the deleted on
setNodeTypeReservoir Transforms a node to RESERVOIR The new node keeps the id,coordinates and elevation of the deleted on
setNodeTypeTank Transforms a node to TANK The new node keeps the id,coordinates and elevation of the deleted on
setNodesConnectingLinksID Sets the IDs of a link's start- and end-nodes
setOptionsAccuracyValue Sets the total normalized flow change for hydraulic convergence
setOptionsCheckFrequency Sets the frequency of hydraulic status checks
setOptionsDampLimit Sets the accuracy level where solution damping begins
setOptionsDemandCharge Sets the energy charge per maximum KW usage
setOptionsDemandPattern Retrieves the default Demand pattern
setOptionsEmitterBackFlowAllowed Sets the option to allow reverse flow through emitters
setOptionsEmitterBackFlowDisallowed Sets the option prevent reverse flow through emitters
setOptionsEmitterExponent Sets the power exponent for the emmitters
setOptionsExtraTrials Sets the extra trials allowed if hydraulics don't converge
setOptionsFlowChange Sets the maximum flow change for hydraulic convergence
setOptionsGlobalEffic Sets the global efficiency for pumps(percent)
setOptionsGlobalPattern Sets the global energy price pattern
setOptionsGlobalPrice Sets the global average energy price per kW-Hour
setOptionsHeadError Sets the maximum head loss error for hydraulic convergence
setOptionsHeadLossFormula Sets the headloss formula
setOptionsLimitingConcentration Sets the limiting concentration for growth reactions
setOptionsMaxTrials Sets the maximum hydraulic trials allowed for hydraulic convergence
setOptionsMaximumCheck Sets the maximum trials for status checking
setOptionsPatternDemandMultiplier Sets the global pattern demand multiplier
setOptionsPipeBulkReactionOrder Sets the bulk water reaction order for pipes
setOptionsPipeWallReactionOrder Sets the wall reaction order for pipes (either 0 or 1)
setOptionsPressureUnits Sets the pressure unit used in Epanet
setOptionsPressureUnitsKPA Set pressure units to KPA and check if the change is possible
setOptionsPressureUnitsMeters Set pressure units to Meters and check if the change is possible
setOptionsPressureUnitsPSI Set pressure units to PSI and check if the change is possible
setOptionsQualityTolerance Sets the water quality analysis tolerance
setOptionsSpecificDiffusivity Sets the specific diffusivity (relative to chlorine at 20 deg C)
setOptionsSpecificGravity Sets the specific gravity
setOptionsSpecificViscosity Sets the specific viscosity
setOptionsStatusReport Sets the status report for epanet
setOptionsStatusReportFull set the status report option to full report
setOptionsStatusReportNo set the status report option to no Report
setOptionsStatusReportNormal set the status report option to normal report
setOptionsTankBulkReactionOrder Sets the bulk water reaction order for tanks
setPattern Sets all of the multiplier factors for a specific time pattern
setPatternComment Sets the comment string assigned to the pattern object
setPatternMatrix Sets all of the multiplier factors for all time patterns
setPatternNameID Sets the name ID of a time pattern given it's index and the new ID
setPatternValue Sets the multiplier factor for a specific period within a time pattern
setQualityType Sets the type of water quality analysis called for
setReport Issues a report formatting command
setReportFormatReset Resets a project's report options to their default values
setReportStatus Sets the level of hydraulic status reporting
setRuleElseAction Sets rule - based control else actions
setRuleEnabled Enables a specific rule in the EPANET model
setRulePremise Sets the premise of a rule - based control
setRulePremiseObjectNameID Sets the ID of an object in a premise of a rule-based control
setRulePremiseStatus Sets the status being compared to in a premise of a rule-based control
setRulePremiseValue Sets the value being compared to in a premise of a rule-based control
setRulePriority Sets rule - based control priority
setRuleThenAction Sets rule - based control then actions
setRules Sets a rule - based control
setTimeClockStartTime Sets the start time for simulation
setTimeHydraulicStep Sets the hydraulic time step
setTimePatternStart Sets the time when time patterns begin
setTimePatternStep Sets the time pattern step
setTimeQualityStep Sets the quality time step
setTimeReportingStart Sets the time when reporting starts
setTimeReportingStep Sets the reporting time step
setTimeRuleControlStep Sets the rule-based control evaluation time step
setTimeSimulationDuration Sets the simulation duration (in seconds)
setTimeStatisticsType Sets the statistic type
setTitle Sets the title lines of the project
setVertex Sets the coordinates of a vertex point in a link within the EPANET model
solveCompleteHydraulics Runs a complete hydraulic simulation with results for all time periods written to the binary Hydraulics file
solveCompleteQuality Runs a complete water quality simulation with results at uniform reporting intervals written to EPANET's binary Output file
splitPipe Splits a pipe, creating two new pipes and adds a junction/node in between
stepQualityAnalysisTimeLeft Advances the water quality simulation one water quality time step
unload unload library and close the EPANET Toolkit system
useHydraulicFile Uses the contents of the specified file as the current binary hydraulics file
writeLineInReportFile Writes a line of text to the EPANET report file
writeReport Writes a formatted text report on simulation results to the Report file

MSX Functions

Function Description
addMSXPattern Adds a new, empty MSX source time pattern to the project
getMSXAreaUnits Retrieves the area units (FT2/M2/CM2)
getMSXAtol Retrieves the absolute concentration tolerance
getMSXCompiler Retrieves the compiler (NONE/VC/GC)
getMSXComputedLinkQualitySpecie Returns the link quality for specific specie
getMSXComputedNodeQualitySpecie Returns the node quality for specific specie
getMSXComputedQualityLink Returns the computed quality for links.
getMSXComputedQualityNode Retrieves the concentration of a chemical species at a specific node of the network at the current simulation time step.
getMSXComputedQualitySpecie Retrieves the quality values for specific specie (e.g getMSXComputedQualitySpecie('CL2'))
getMSXComputedQualitySpecie Retrieves the quality values for specific specie (e.g getMSXComputedQualitySpecie(['CL2']))
getMSXConstantsCount Retrieves the number of constants
getMSXConstantsIndex Retrieves the internal index number of constants (given its ID name)
getMSXConstantsNameID Retrieves the ID name of constants (given its internal index number)
getMSXConstantsValue Retrieves the constant's value.
getMSXCoupling Retrieves the coupling (FULL/NONE)
getMSXEquationsPipes Retrieves the species dynamics in pipes
getMSXEquationsTanks Retrieves the species dynamics in tanks
getMSXEquationsTerms Retrieves the species dynamics in terms
getMSXError Returns the text for an error message given its error code
getMSXLinkInitqualValue Retrieves the initial concentration of chemical species assigned to links of the pipe network
getMSXNodeInitqualValue Retrieves the initial concentration of chemical species assigned to nodes
getMSXOptions Retrieves all the msx option parameters
getMSXParametersCount Retrieves the number of parameters
getMSXParametersIndex Retrieves the indices of parameters
getMSXParametersNameID Retrieves the ID name of parameters
getMSXParametersPipesValue Retrieves the value of reaction parameters for pipes
getMSXParametersTanksValue Retrieves the value of reaction parameters for tanks
getMSXPattern Retrieves the multiplier factor for all patterns and all times
getMSXPatternValue Retrieves the multiplier at a specific time period for a given source time pattern
getMSXPatternsCount Retrieves the number of patterns
getMSXPatternsIndex Retrieves the indices of patterns
getMSXPatternsLengths Retrieves the number of time periods in all or some patterns
getMSXPatternsNameID Retrieves the patterns IDs
getMSXRateUnits Retrieves the rate/time units (SEC/MIN/HR/DAY)
getMSXRtol Retrieves the relative concentration tolerance
getMSXSolver Retrieves the solver method.
getMSXSourceLevel Retrieves the value of all nodes source level
getMSXSourceNodeNameID Retrieves the ID label of all nodes
getMSXSourcePatternIndex Retrieves the value of all node source pattern index
getMSXSourceType Retrieves the value of all node source type
getMSXSources Retrieves Msx sources
getMSXSpeciesATOL Retrieves the atol
getMSXSpeciesConcentration Retrieves the concentration of chemical species for nodes and links
getMSXSpeciesCount Retrieves the number of species
getMSXSpeciesIndex Retrieves the indices of species
getMSXSpeciesNameID Retrieves the species IDs
getMSXSpeciesRTOL Retrieves the rtol
getMSXSpeciesType Retrieves the type of all species (BULK/WALL)
getMSXSpeciesUnits Retrieves the species mass units
getMSXTimeStep Retrieves the time step
getMethods Returns all methods of epanet
loadMSXFile Loads an msx file
initializeMSXQualityAnalysis Initializes the MSX system before solving for water quality results in step-wise fashion
plotMSXSpeciesLinkConcentration Plots concentration of species for links over time.
plotMSXSpeciesNodeConcentration Plots concentration of species for nodes over time.
saveMSXFile Saves the data associated with the current MSX project into a new MSX input file
saveMSXQualityFile Saves water quality results computed for each node, link and reporting time period to a named binary file
setMSXAreaUnitsCM2 Sets area units to CM2
setMSXAreaUnitsFT2 Sets area units to FT2
setMSXAreaUnitsM2 Sets area units to M2
setMSXAtol Sets the value of Atol
setMSXCompilerGC Sets compilet to GC
setMSXCompilerNONE Sets compiler to None
setMSXCompilerVC Sets compiler to VC
setMSXConstantsValue Assigns a new value to a specific reaction constant
setMSXCouplingFULL Sets coupling option to FULL
setMSXCouplingNONE Sets coupling option to NONE
setMSXLinkInitqualValue Assigns an initial concentration of chemical species to links
setMSXNodeInitqualValue Assigns an initial concentration of chemical species to nodes
setMSXParametersPipesValue Assigns a value to a particular reaction parameter for given pipes
setMSXParametersTanksValue Assigns a value to a particular reaction parameter for given tanks
setMSXPattern Sets all of the multiplier factors for a specific time pattern
setMSXPatternMatrix Sets the multiplier factors for all patterns
setMSXPatternValue Assigns a new value to the multiplier for a specific time period in a given MSX source time pattern
setMSXRateUnitsDAY Sets rate units to DAY
setMSXRateUnitsHR Sets rate units to HR
setMSXRateUnitsMIN Sets rate units to MIN
setMSXRateUnitsSEC Sets rate units to SEC
setMSXRtol Sets the value of Rtol
setMSXSolverEUL Sets solver to EUL (standard Euler integrator)
setMSXSolverRK5 Sets solver to RK5 (Runge-Kutta 5th order integrator)
setMSXSolverROS2 Sets solver to ROS2 (2nd order Rosenbrock integrator)
setMSXSources Sets the attributes of an external source of a particular chemical species to a specific node of the pipe network
setMSXTimeStep Sets time step
solveMSXCompleteHydraulics Solves for system hydraulics over the entire simulation period saving results to an internal scratch file
solveMSXCompleteQuality Solves for water quality over the entire simulation period and saves the results to an internal scratch file
stepMSXQualityAnalysisTimeLeft Advances the water quality solution through a single water quality time step when performing a step-wise simulation
useMSXHydraulicFile Uses a previously saved EPANET hydraulics file as the source of hydraulic information
unloadMSX Unloads MSX file
writeMSXFile Write a new MSX file
writeMSXReport Writes MSX report

List of MSX Functions

Function Description
addMSXPattern Adds a new, empty MSX source time pattern to the project
getMSXAreaUnits Retrieves the area units (FT2/M2/CM2)
getMSXAtol Retrieves the absolute concentration tolerance
getMSXCompiler Retrieves the compiler (NONE/VC/GC)
getMSXComputedLinkQualitySpecie Returns the link quality for specific specie
getMSXComputedNodeQualitySpecie Returns the node quality for specific specie
getMSXComputedQualityLink Returns the computed quality for links.
getMSXComputedQualityNode Retrieves the concentration of a chemical species at a specific node of the network at the current simulation time step.
getMSXComputedQualitySpecie Retrieves the quality values for specific specie (e.g getMSXComputedQualitySpecie('CL2'))
getMSXComputedQualitySpecie Retrieves the quality values for specific specie (e.g getMSXComputedQualitySpecie(['CL2']))
getMSXConstantsCount Retrieves the number of constants
getMSXConstantsIndex Retrieves the internal index number of constants (given its ID name)
getMSXConstantsNameID Retrieves the ID name of constants (given its internal index number)
getMSXConstantsValue Retrieves the constant's value.
getMSXCoupling Retrieves the coupling (FULL/NONE)
getMSXEquationsPipes Retrieves the species dynamics in pipes
getMSXEquationsTanks Retrieves the species dynamics in tanks
getMSXEquationsTerms Retrieves the species dynamics in terms
getMSXError Returns the text for an error message given its error code
getMSXLinkInitqualValue Retrieves the initial concentration of chemical species assigned to links of the pipe network
getMSXNodeInitqualValue Retrieves the initial concentration of chemical species assigned to nodes
getMSXOptions Retrieves all the msx option parameters
getMSXParametersCount Retrieves the number of parameters
getMSXParametersIndex Retrieves the indices of parameters
getMSXParametersNameID Retrieves the ID name of parameters
getMSXParametersPipesValue Retrieves the value of reaction parameters for pipes
getMSXParametersTanksValue Retrieves the value of reaction parameters for tanks
getMSXPattern Retrieves the multiplier factor for all patterns and all times
getMSXPatternValue Retrieves the multiplier at a specific time period for a given source time pattern
getMSXPatternsCount Retrieves the number of patterns
getMSXPatternsIndex Retrieves the indices of patterns
getMSXPatternsLengths Retrieves the number of time periods in all or some patterns
getMSXPatternsNameID Retrieves the patterns IDs
getMSXRateUnits Retrieves the rate/time units (SEC/MIN/HR/DAY)
getMSXRtol Retrieves the relative concentration tolerance
getMSXSolver Retrieves the solver method.
getMSXSourceLevel Retrieves the value of all nodes source level
getMSXSourceNodeNameID Retrieves the ID label of all nodes
getMSXSourcePatternIndex Retrieves the value of all node source pattern index
getMSXSourceType Retrieves the value of all node source type
getMSXSources Retrieves Msx sources
getMSXSpeciesATOL Retrieves the atol
getMSXSpeciesConcentration Retrieves the concentration of chemical species for nodes and links
getMSXSpeciesCount Retrieves the number of species
getMSXSpeciesIndex Retrieves the indices of species
getMSXSpeciesNameID Retrieves the species IDs
getMSXSpeciesRTOL Retrieves the rtol
getMSXSpeciesType Retrieves the type of all species (BULK/WALL)
getMSXSpeciesUnits Retrieves the species mass units
getMSXTimeStep Retrieves the time step
getMethods Returns all methods of epanet
loadMSXFile Loads an msx file
initializeMSXQualityAnalysis Initializes the MSX system before solving for water quality results in step-wise fashion
plotMSXSpeciesLinkConcentration Plots concentration of species for links over time.
plotMSXSpeciesNodeConcentration Plots concentration of species for nodes over time.
saveMSXFile Saves the data associated with the current MSX project into a new MSX input file
saveMSXQualityFile Saves water quality results computed for each node, link and reporting time period to a named binary file
setMSXAreaUnitsCM2 Sets area units to CM2
setMSXAreaUnitsFT2 Sets area units to FT2
setMSXAreaUnitsM2 Sets area units to M2
setMSXAtol Sets the value of Atol
setMSXCompilerGC Sets compilet to GC
setMSXCompilerNONE Sets compiler to None
setMSXCompilerVC Sets compiler to VC
setMSXConstantsValue Assigns a new value to a specific reaction constant
setMSXCouplingFULL Sets coupling option to FULL
setMSXCouplingNONE Sets coupling option to NONE
setMSXLinkInitqualValue Assigns an initial concentration of chemical species to links
setMSXNodeInitqualValue Assigns an initial concentration of chemical species to nodes
setMSXParametersPipesValue Assigns a value to a particular reaction parameter for given pipes
setMSXParametersTanksValue Assigns a value to a particular reaction parameter for given tanks
setMSXPattern Sets all of the multiplier factors for a specific time pattern
setMSXPatternMatrix Sets the multiplier factors for all patterns
setMSXPatternValue Assigns a new value to the multiplier for a specific time period in a given MSX source time pattern
setMSXRateUnitsDAY Sets rate units to DAY
setMSXRateUnitsHR Sets rate units to HR
setMSXRateUnitsMIN Sets rate units to MIN
setMSXRateUnitsSEC Sets rate units to SEC
setMSXRtol Sets the value of Rtol
setMSXSolverEUL Sets solver to EUL (standard Euler integrator)
setMSXSolverRK5 Sets solver to RK5 (Runge-Kutta 5th order integrator)
setMSXSolverROS2 Sets solver to ROS2 (2nd order Rosenbrock integrator)
setMSXSources Sets the attributes of an external source of a particular chemical species to a specific node of the pipe network
setMSXTimeStep Sets time step
solveMSXCompleteHydraulics Solves for system hydraulics over the entire simulation period saving results to an internal scratch file
solveMSXCompleteQuality Solves for water quality over the entire simulation period and saves the results to an internal scratch file
stepMSXQualityAnalysisTimeLeft Advances the water quality solution through a single water quality time step when performing a step-wise simulation
useMSXHydraulicFile Uses a previously saved EPANET hydraulics file as the source of hydraulic information
unloadMSX Unloads MSX file
writeMSXFile Write a new MSX file
writeMSXReport Writes MSX report

List of EPANET 2.012 Functions Supported

Function Description
ENaddpattern Adds a new time pattern to the network
ENclose Closes down the Toolkit system (including all files being processed)
ENcloseH Closes the hydraulic analysis system, freeing all allocated memory
ENcloseQ Closes the water quality analysis system, freeing all allocated memory
ENepanet Runs a complete EPANET simulation
ENgetcount Retrieves the number of network components of a specified type
ENgetcontrol Retrieves the parameters of a simple control statement
ENgeterror Retrieves the text of the message associated with a particular error or warning code
ENgetflowunits Retrieves a code number indicating the units used to express all flow rates
ENgetlinkid Retrieves the ID label of a link with a specified index
ENgetlinkindex Retrieves the index of a link with a specified ID
ENgetlinknodes Retrieves the indexes of the end nodes of a specified link
ENgetlinktype Retrieves the link-type code for a specific link
ENgetlinkvalue Retrieves the value of a specific link parameter
ENgetnodeid Retrieves the ID label of a node with a specified index
ENgetnodeindex Retrieves the index of a node with a specified ID
ENgetnodetype Retrieves the node-type code for a specific node
ENgetnodevalue Retrieves the value of a specific link parameter
ENgetoption Retrieves the value of a particular analysis option
ENgetpatternid Retrieves the ID label of a particular time pattern
ENgetpatternindex Retrieves the index of a particular time pattern
ENgetpatternlen Retrieves the number of time periods in a specific time pattern
ENgetpatternvalue Retrieves the multiplier factor for a specific time period in a time pattern
ENgetqualtype Retrieves the type of water quality analysis called for
ENgettimeparam Retrieves the value of a specific analysis time parameter
ENgetversion Retrieves the version number
ENinitH Initializes hydraulic analysis
ENinitQ Initializes water quality analysis
ENnextH Determine time (in seconds) until next hydraulic event
ENnextQ Advances WQ simulation to next hydraulic event
ENopen Opens EPANET input file & reads in network data
ENopenH Sets up data structures for hydraulic analysis
ENopenQ Sets up data structures for WQ analysis
ENreport Writes simulation report to the report file
ENresetreport Resets report options to default values
ENrunH Run a hydraulic solution period
ENrunQ Retrieves hydraulic & WQ results at time t
ENsaveH Saves hydraulic results to binary file
ENsavehydfile Copies binary hydraulics file to disk
ENsaveinpfile Saves current data to "INP" formatted text file
ENsetcontrol Specify parameters to define a simple control
ENsetlinkvalue Set a proprty value for a link
ENsetnodevalue Set a property value for a node
ENsetoption Set a value for an anlysis option
ENsetpattern Set multipliers for a specific pattern
ENsetpatternvalue Set the multiplier for a specific pattern at a specific period
ENsetqualtype Sets the type of water quality analysis called
ENsetreport Processes a reporting format command
ENsetstatusreport Sets the level of hydraulic status reporting
ENsettimeparam Set the value for a time parameter
ENsolveH Solves the network hydraulics for all time periods
ENsolveQ Solves for network water quality in all time periods
ENstepQ Advances WQ simulation by a single WQ time step
ENusehydfile Opens previously saved binary hydraulics file
ENwriteline Writes line of text to the report file

Back to top

List of EPANET 2.1 Functions Supported

Function Description
ENaddcurve Adds a new curve appended to the end of the existing curves
ENgetaveragepatternvalue Retrieves the average value of a pattern
ENgetbasedemand Retrieves the nodes base demand for a category
ENgetcoord Retrieves coordinate x, y for a node
ENgetcurve Retrieves a curve's properties
ENgetcurveid Retrieves ID of a curve with specific index
ENgetcurveindex Retrieves index of curve with specific ID
ENgetcurvelen Retrieves number of points in a curve
ENgetcurvevalue Retrieves x,y point for a specific point number and curve
ENgetdemandpattern Retrieves the index of a demand pattern for a specific demand category of a node
ENgetheadcurveindex Retrieves index of a head curve for specific link index
ENgetnumdemands Retrieves the number of demand categories for a node
ENgetpumptype Retrieves the type of a pump for specific link index
ENgetqualinfo Retrieves quality analysis information (type, chemical name, units, trace node ID)
ENgetstatistic Retrieves hydraulic simulation statistic
ENsetbasedemand Sets the nodes base demand for a category
ENsetcoord Sets coordinate x, y for a node
ENsetcurve Sets x,y values for a specific curve
ENsetcurvevalue Sets x,y point for a specific point and curve

Back to top

List of EPANET 2.2 Functions Supported

Function Description
ENaddcontrol Specify parameters to add a new simple control
ENaddlink Adds a new link
ENaddnode Adds a new node
ENaddrule Adds a new rule-based control to a project
ENadddemand Appends a new demand to a junction node demands list
ENclearreport Clears the contents of a project's report file
ENcopyreport Copies the current contents of a project's report file to another file
ENdeletelink Deletes a link
ENdeletenode Deletes a node
ENdeletedemand Deletes a demand from a junction node
ENsetcurveid Changes the ID name of a data curve given its index
ENsetpatternid Changes the ID name of a time pattern given its index
ENsetdemandpattern Sets the index of the demand pattern assigned to a node for a category index
ENsetheadcurveindex Sets the curve index for a specified pump index
ENgetcurvetype Retrieves the type of a curve
ENgetdemandindex Retrieves the index of a node's named demand category
ENgetpremise Gets the properties of a premise in a rule-based control
ENgetelseaction Gets the properties of an ELSE action in a rule-based control
ENgetruleid Gets the ID name of a rule-based control given its index
ENgetrule Retrieves summary information about a rule-based control
ENgetthenaction Gets the properties of a THEN action in a rule-based control
ENsetflowunits Sets the flow units
ENgetdemandmodel Retrieves the type of demand model in use and its parameters
ENsetdemandmodel Sets the type of demand model to use and its parameters
ENsetelseaction Sets the properties of an ELSE action in a rule-based control
ENsetnodeid Change the ID name for a node
ENsetlinkid Change the ID name for a link
ENsetpipedata Sets a group of properties for a pipe link
ENsetpremise Sets the properties of a premise in a rule-based control
ENsetpremiseindex Sets the index of an object in a premise of a rule-based control
ENsetpremisestatus Sets the status being compared to in a premise of a rule-based control
ENsetpremisevalue Sets the value in a premise of a rule-based control
ENsetrulepriority Sets the priority of a rule-based control
ENsettankdata Sets a group of properties for a tank node
ENsetthenaction Sets the properties of a THEN action in a rule-based control
ENgettitle Retrieves the title lines of the project
ENsettitle Sets the title lines of the project
ENsetlinknodes Sets the indexes of a link's start- and end-nodes
ENsetlinktype Changes the type of a particular link (e.g. pipe to pump)
ENgetdemandname Gets the name of a node's demand category
ENsetdemandname Assigns a name to a node's demand category
ENgetcomment Retrieves the comment string assigned to the object (NODE, LINK, TIMEPAT or CURVE)
ENsetcomment Sets the comment string assigned to the object (NODE, LINK, TIMEPAT or CURVE)
ENdeletepattern Deletes a time pattern from a project
ENdeletecurve Deletes a data curve from the project
ENdeletecontrol Deletes an existing simple control
ENdeleterule Deletes an existing rule-based control
ENsetjuncdata Sets a group of properties for a junction node
ENgetvertex Retrieves the coordinate's of a vertex point assigned to a link
ENgetvertexcount Retrieves the number of internal vertex points assigned to a link
ENsetvertices Assigns a set of internal vertex points to a link
ENgetresultindex Retrieves the order in which a node's or link's results were saved to an output file
ENinit Initializes an EPANET project that isn't opened with an input file

Back to top

List of EPANET 2.3 Functions Supported

Function Description
ENgetcontrolenabled Get enabled/disabled flag for a simple control by index (1 = enabled, 0 = disabled)
ENgetlinkvalues Bulk-retrieve property values for all links for a given link property code
ENgetnodevalues Bulk-retrieve property values for all nodes for a given node property code
ENgetruleenabled Get enabled/disabled flag for a rule-based control by rule index
ENloadpatternfile Load time patterns from an external file into the current project under a specific pattern ID
ENopenX Open an input file even if it has formatting errors (lenient parsing mode)
ENsetcontrolenabled Enable/disable a specific simple control by index
ENsetcurvetype Set the type of a curve object (volume, pump, efficiency, headloss, general, valve)
ENsetruleenabled Enable/disable a rule by rule index
ENsetvertex Set the coordinates of a link’s intermediate vertex (polyline point) by vertex index
ENtimetonextevent Return the type of event that terminates the current time step (hydraulic step, water quality step, tank level event, control event)

List of EPANET MSX Functions API

Function Description
MSXaddpattern Adds a new empty MSX source time pattern to an MSX project
MSXclose Close .msx file
MSXerror Retrieves the MSX erorr message for specific erorr code
MSXgetID Retrieves the ID name of an object given its internal index number
MSXgetIDlen Retrieves the number of characters in the ID name of an MSX object given its internal index number
MSXgetconstant Retrieves the value of a particular rection constant
MSXgetcount Retrieves the number of objects of a specific type
MSXgeterror Returns the text for an error message given its error code
MSXgetindex Retrieves the number of objects of a specific type
MSXgetinitqual Retrieves the intial concetration of a particular chemical species assigned to a specific node or link of the pipe network
MSXgetparameter Retrieves the value of a particular reaction parameter for a given pipe
MSXgetpatternlen Retrieves the number of time periods within a source time pattern
MSXgetpatternvalue Retrieves the multiplier at a specific time period for a given source time pattern
MSXgetqual Retrieves a chemical species concentration at a given node or the average concentration along a link at the current sumulation time step
MSXgetsource Retrieves information on any external source of a particular chemical species assigned to a specific node or link of the pipe network
MSXgetspecies Retrieves the attributes of a chemical species given its internal index number
MSXinit Initialize the MSX system before solving for water quality results in the step-wise fashion
MSXopen Opens .MSX file
MSXreport Writes water quality simulations results as instructed by MSX input file to a text file
MSXsavemsxfile Saves the data associated with the current MSX project into a new MSX input file
MSXsaveoutfile Saves water quality results computed for each node, link and reporting time period to a named binary file
MSXsetconstant Assigns a new value to a specific reaction constant
MSXsetinitqual Assigns an initial concetration of a particular chemical species node or link of the pipe network
MSXsetparameter Assigns a value to a particular reaction parameter for a given pipe or tank within the pipe network
MSXsetpattern Assigns a new set of multipliers to a given MSX source time pattern
MSXsetpatternvalue Assigns a new value to the multiplier for a specific time period in a given MSX source time pattern
MSXsetsource Sets the attributes of an external source of particular chemical species to specific node of the pipe network
MSXsolveH Solves for system hydraulics over the entire simulation period saving results to an internal scratch file
MSXsolveQ Solves for water quality over the entire simulation period and saves the results to an internal scratch file
MSXstep Advances the water quality solution through a single water quality time step when performing a step-wise simulation
MSXusehydfile Uses a previously saved EPANET hydraulics file as the source of hydraulic information

Back to top